Full-text Article (Subscribers only)
Full-text article (287 kB)
(subscribers only)

Buy article on-line and get access immediately
Buy article on-line for £11.75
(get immediate access)

Search
Search

Go Back

Eur. J. Mass Spectrom. 4, 475 - 486 (1998)

Comparison of electrospray ionisation mass spectrometry with matrix-assisted laser desorption ionisation mass spectrometry and size exclusion chromatography for the characterisation of polyester resins

Susan M. Hunt and Margaret M. Sheil*
Department of Chemistry, University of Wollongong, Wollongong, NSW, 2522 Australia.
Peter J. Derrick
Institute of Mass Spectrometry and Department of Chemistry, University of Warwick, Coventry CV4 7AL, UK.

ABSTRACT:
A series of 17 polyester paint resins have been analysed by electrospray ionisation (ESI) and matrix-assisted laser desorption (MALDI) mass spectrometry to compare the structural and molecular weight data derived from each technique. Optimisation of sample preparation and laser power were found to be important factors in obtaining constant molecular weight distributions by MALDI. With ESI, we have shown previously that the voltage applied to the sampling cone (or orifice) has a major influence on the observed ion distributions. Using sampling cone voltages at which ion currents owing to the polymer were at a maximum, number average (Mn) and weight average (Mw) molecular weight values estimated by ESI were similar to, or slightly higher than those determined by MALDI. The use of size exclusion chromatography (SEC) for fractionation of polyester samples prior to ESI or MALDI analysis, however, showed that both techniques significantly underestimate the average molecular weights of the polyesters. This is consistent with other studies that have shown that ESI and MALDI are unsuitable for determining molecular weights of polydisperse polymers. Differences in the relative abundances of branched and cyclic species in ESI versus MALDI mass spectra were also noted. These differences were accentuated in the data obtained for the SEC fractions which showed reduced sensitivity for branched species in ESI (especially at higher masses) and some discrimination against masses <500 Da in MALDI. These data indicate that the different sample preparation and/or ionisation processes in MALDI and ESI may result in enhancement/suppression of closely related species to differing extents. Hence, where possible, it would be useful to employ both techniques to ensure complete characterisation of complex polymer samples.

Keywords: Polymers, polyesters, size exclusion chromatography, electrospray ionisation, matrix-assisted laser desorption ionisation, mass spectrometry

You can now buy this paper on-line in PDF format; it costs only £11.75. Just click on the BUY on-line button. You can pay on-line through a secure server and get access immediately.


© IM Publications
Any problems? E-mail .